BOLTPREP Pty Ltd © 2006
Physical
Weight: 13.5 ounces (with batteries).
Size:
Width (2.5 in/63.5 mm)
Height (6.5 in/165 mm)
Depth (1.24 in/31.5 mm)
Operating Temperature:
-
Keyboard:
Membrane switch with twelve tactile keys.
Case: E
xtruded aluminum body with nickel plated aluminum end caps (gasket sealed).
Data Output:
Bi-
Display:
1/8in VGA grayscale display (240 x 160 pixels); viewable area 2.4 x 1.8in (62 x 45.7mm); EL backlit (on/off/auto invert).
Ultrasonic Specifications
Measurement Modes:
Pulse-
Pulse-
Pulser:
Square wave pulser with adjustable pulse width (spike, thin, wide).
Receiver:
Manual or AGC gain control with 40dB range.
Timing: 1
0 bit 250 MHz digitizer.
Transducer
Transducer Types:
Dual Element (1 to 10 MHz).
Locking quick disconnect “00” LEMO connectors. Standard 4 foot cable.
Custom transducers and cable lengths available for special applications.
Measuring
Range: From 1 to 96 inches (25.4 to 244 cm).
Quantities:
Time -
Elongation -
Load -
Stress -
%Strain -
Resolution: +/-
Velocity Range: 0.0492 to .3937 inches/microsecond (in/μs) (1250 to 9,999 meters/sec).
Fixed, Single, and Two-
Units: English & Metric / Farenheit & Centigrade.
Display
A-
Large Digits: Display and toggle between nanoseconds, elongation, load, stress, and strain; Digit Height: 0.400 inch (10mm).
Limits Bar (alarm limits): Set Hi & Lo alarm limits for displaying an acceptable
toler-
Repeatability Bar Graph: Bar graph indi-
Data Logger
Total of 8,000 bolts in multiple bolt groups. Stores both waveform views, nanoseconds, elongation, load, stress, strain and all gauge settings for each reading.
Memory: 16 megabit non-
Transducer
Transducer types:
Single element (1 MHz to 10 MHz & 1/8 to 1inch diameters). Magnetic & Non-
Glue-
Locking quick disconnect “00” LEMO connectors. Standard 10 foot cable.
Custom transducers available for special applications.
Temperature probe for automatic temperature compensation.
Features
Setups:
64 custom user defined setups; Factory set-
Gate:
Gate used to fine adjust where the detec-
Alarm Limits:
Set Hi and Lo tolerances with audible beeper, viewable scan bar, and visual LEDs.
Auto Set:
Locates the detection signal, optimizes the gain setting, and adjusts the overall
display to show the waveform and detec-
Field Calibration:
Vector & linear regression.
Certification
Factory calibration traceable to NIST & MIL-
Warranty
2 year limited
Ultrasonically measures the actual elongation produced by tightening a threaded fastener.